DIESEL GENERATING SET

PGFP40SS (ULTRASILENT TYPE)

 

MODEL PGFT40SS
Prime Power(50Hz) 36KW /36KVA
Standby Power(50Hz) 40KW /40KVA
Prime Current (A) 156.5
Standby Current (A) 172
Rated Voltage (V) 230
Power Factor 1
Have Questions before buying this product? Enquire Now
Category:

Description

STANDARDS AND AMBIENT CONDITIONS OF REFERENCE

Manufacturer is in conformity with the following systems in daily operation:
1, Quality Management System Certificate GB/T19001-2016/ISO9001:2015;
2. Environmental Management System Certificate GB/T24001-2016/ISO14001:2015;
3. Occupational Health and Safety Management System Certificate GB/T45001-2020/ISO45001:2018;
4. Social Responsibility Certification SA8000-2014

Gensets are compliant with EC mark which includes the following directives:
1. 2006/42/EC Machinery safety;
2. 2014/30/EU Electromagnetic compatibility;
3. 2014/35/EU Electrical equipment designed for use within certain voltage limits;
4. 2000/14/EC Sound power level. Noise emission outdoor equipment.
5. ISO8528 Reciprocating Internal Combustion Engine Driven Alternating Current Generating Sets.

Ambient conditions of reference according to ISO8528-1:2018:
25℃, below 1000m altitude, 30% relative humidity

POWER DEFINITION

Prime Power (PRP):
Prime Power is the maximum power available for unlimited hours of usage in a variable load application.
The average load factor should not exceed 70% of the engine’s PRP power rating during any 24 hour
period An overload capability of 10% is available however, this is limited to 1 hour within every12 hour
period.

Emergency Standby Power Rating (ESP):
Emergency Standby Power is the maximum power available for a varying load for the duration of a main
power network failure. The average load factor over 24 hours of operation should not exceed 70% of the
engine’s ESP power rating. Typical operational hours of the engine is 200hours per year, with a
maximum usage of 500hours per year. This includes an annual maximum of 25 hours per year at the
ESP power rating. No overload capability is allowed. The engine is not to be used for sustained utility
paralleling applications.

NOTE
POWERGEN has the right to modify any data and features without prior notice.
Technical data and configuration described in this flysheet is basic, the actual data and configuration is
based on specific case and may different from the flysheet.
The photos and illustrations are based on standard configuration, the actual product may different from
them.

GENERATINGSETPERFORMANCE
Relative Voltage Setting Range ≤ ±5%
Voltage Deviation, Steady State ≤ ±2.5%
Transient Voltage Deviation (100% Sudden Reduce) ≤ +25%
Transient Voltage Deviation (Sudden Increase) ≤ -20%
Voltage Recovery Time ≤ 6S
Frequency Droop ≤ 5%
Steady-State Frequency Band ≤ 1%
Sudden Frequency Warp (100% Sudden Reduce) ≤ +12%
Sudden Frequency Warp (Sudden Increase) ≤ -10%
Frequency Recovery Time (100% Sudden Reduce) ≤ 5S
Frequency Recovery Time (Sudden Increase) ≤ 5S

 

Items Standard Optional
Engine 50℃ Radiator Tank 55℃
Expansion Tank
Cold Starting
Water-Fuel Separator
Dry Type Air Filter
Fuel Filter
Oil Filter
Alternator Insulation Class H PMG
Marine Standard
Auxiliary Winding AVR, 2/3 Pitch
Cold Starting Controller
Autostart Control Module AMF
Real-Time Running Data
Remote Control
Synchronization
Electrical CE Socket with Circuit Breaker IP67
MCCB with RCD
Voltage Selection Switch
Terminal Output Built-in / External ATS
Fully Protected Earthing
IT / TN Switch
Lead-Acid Maintenance-Free Battery
Lightning Protection
Canopy Silent Canopy Ultrasilent Canopy
Type Stationary Mobile

Reviews

There are no reviews yet.

Be the first to review “DIESEL GENERATING SET”

Your email address will not be published. Required fields are marked *