MODEL PGFT40SS
Prime Power(50Hz) 36KW /36KVA
Standby Power(50Hz) 40KW /40KVA
Prime Current (A) 156.5
Standby Current (A) 172
Rated Voltage (V) 230
Power Factor 1

STANDARDS AND AMBIENT CONDITIONS OF REFERENCE

Manufacturer is in conformity with the following systems in daily operation:

1, Quality Management System Certificate GB/T19001-2016/ISO9001:2015;

  1. Environmental Management System Certificate GB/T24001-2016/ISO14001:2015;
  2. Occupational Health and Safety Management System Certificate GB/T45001-2020/ISO45001:2018;
  3. Social Responsibility Certification SA8000-2014

Gensets are compliant with EC mark which includes the following directives:

  1. 2006/42/EC Machinery safety;
  2. 2014/30/EU Electromagnetic compatibility;
  3. 2014/35/EU Electrical equipment designed for use within certain voltage limits;
  4. 2000/14/EC Sound power Noise emission outdoor equipment.
  5. ISO8528 Reciprocating Internal Combustion Engine Driven Alternating Current Generating

Ambient conditions of reference according to ISO8528-1:2018:

25℃, below 1000m altitude, 30% relative humidity

POWER DEFINITION

Prime Power (PRP):

Prime Power is the maximum power available for unlimited hours of usage in a variable load application. The average load factor should not exceed 70% of the engine’s PRP power rating during any 24 hour period An overload capability of 10% is available however, this is limited to 1 hour within every12 hour period.

Emergency Standby Power Rating (ESP):

Emergency Standby Power is the maximum power available for a varying load for the duration of a main power network failure. The average load factor over 24 hours of operation should not exceed 70% of the engine’s ESP power rating. Typical operational hours of the engine is 200hours per year, with a maximum usage of 500hours per year. This includes an annual maximum of 25 hours per year at the ESP power rating. No overload capability is allowed. The engine is not to be used for sustained utility paralleling applications.

NOTE

POWERGEN has the right to modify any data and features without prior notice.

Technical data and configuration described in this flysheet is basic, the actual data and configuration is based on specific case and may different from the flysheet.

The photos and illustrations are based on standard configuration, the actual product may different from them.

GENERATING SET PERFORMANCE
Relative Voltage Setting Range ≤±5%
Voltage Deviation, Steady State ≤±2.5%
Transient Voltage Deviation (100%Sudden Reduce) ≤+25%
Transient Voltage Deviation (Sudden Increase) ≤-20%
Voltage Recovery Time ≤6S
Frequency Droop ≤5%
Steady-state frequency band ≤1%
Sudden Frequency Warp (100% Sudden Reduce: ≤+12%
Sudden Frequency Warp (Sudden Increase) ≤-10%
Frequency Recovery Time (100% Sudden Reduce) ≤5S
Frequency Recovery Time (Sudden Increase) ≤5S

STANDARD CONFIGURATION AND OPTIONAL CONFIGURATION

Items Standard Optional
Engine 50°C radiator tank

Expansion tank

Water-fuel separator

Dry type air filter, fuel filter, oil filter
55°C

Cold starting
Alternator Insulation class H PMG
Marine standard Auxiliary winding
AVR, 2/3 pitch Cold Starting
Controller Auto start control module AMF
Real time running data Remote control
Synchronization
Electrical CEE Socket with Circuit Breaker IP67 Voltage Selection Switch
MCCB with RCD Built-in / external ATS
Terminal Output IT/TN Switch
Fully protected earthing Lightning protection
Lead-acid maintenance free battery
Canopy
Silent/Ultra silent canopy Stationary Mobile
Electrophoresis carbon steel canopy
Stainless steel hardware Zinc alloy
Removable service door
Forklift slots and hanging holes
Fuel Tank
Base-frame daily tank Customized larger tank
Bunded tank Automatic refueling
ENGINE DATA
Manufacturer FPT
Model R38MSNS01.55A01
Prime Power 55kW@1500rpm
Engine type 4-cycle diesel
Aspiration type Turbocharged
Injection Type Direct
Number of Cylinders 4
Cylinder Arrangement Vertical in-line
Displacement 3.76
Bore and Stroke 102mm*115mm
Compression Ratio 17.5:1
Governor type Mechanical
Starting System DC12V
Oil sump capacity (max) 8L
Fuel Consumption 100% PRP 215 g/kWh
Fuel Consumption 80% PRP 185 g/kWh
Fuel Consumption 50% PRP 185 g/kWh
ALTERNATOR DATA
Manufacturer: POWERGEN
Model: DG224E
Rated Power: 36 kW
Connecting Type: Single Phase
Poles: 4
Power Factor: 1
Protection Grade: IP23
Winding Standard 2/3 pitch
Exciter Type: Self-excitation, brushless
Voltage Regulator: AVR
Insulation: H
Bracket type: Single bearing
TIF: < 50
THF: < 2%

Note: The rated power of alternator is based on ambient temperature is lower than 40℃and altitude is

less than 1000m, otherwise the power must be modified accordingly.

Dimension And weight

Ultra Silent Type

Overall Size (LXWXH) (mm): 2700*1100*1400 Net weight: 1200kg

Fuel tank capacity: 145L

Control Panel

Smartgen HGM4010

HGM4000N series genset controllers integrate digitization, intelligentization and network technology which are used for genset automation and monitor control system of single unit to achieve automatic start/stop, data measurement, alarm protection and etc. functions. This series adopt micro-processor technology with precision parameters measuring, fixed value adjustment, time setting and set value adjusting and etc. All parameters can be configured from front panel or through programmable interface (USB or RS485 interface) via PC.

Interested in the Diesel Generating Set PGFP42S3(SILENT TYPE) ?

Contact our team today for pricing, availability, technical specifications, and expert suppor

Request a Quote ↓

    Cart
  • Your cart is empty Browse Shop
    Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
    • Image
    • SKU
    • Rating
    • Price
    • Stock
    • Availability
    • Add to cart
    • Description
    • Content
    • Weight
    • Dimensions
    • Additional information
    Click outside to hide the comparison bar
    Compare